Comparison of DMX over IP protocols

From OpenDMX.net
Jump to: navigation, search
Protocol Specification Available Max Universes Ports per Device DMX Encoding Multi-source merging Transport Method Port
ArtNet 1 Yes 255 4 No Yes, HTP or LTP Subnet broadcast 6454
ArtNet 2 Yes 255 4 No Yes, HTP or LTP Subnet broadcast or Unicast [1] 6454
ArtNet 3 Yes 32768 4 No Yes, HTP or LTP Subnet broadcast or Unicast [2] 6454
E1.31 / ACN Yes [3] 63999 No limit No Yes, per channel merging Multicast [4] 5568
ETCNet2 No 64 [5]  ? Yes Multicast 6107
ESP Net Yes 255  ? Yes No Subnet broadcast 3333
Pathport No 128 [6] 2? No LTP only? Multicast [7] 3792
Sandnet No 65025 2 Yes  ? Multicast [8] 37900 (data) or 37895 (control)
ShowNet No 36  ? Yes  ? Subnet broadcast 2501


  1. Unicast with ArtNet II up to a limit
  2. Unicast with ArtNet II up to a limit
  3. Costs $40 US
  4. One universe per address, 239.255.0.1 - 239.255.249.255
  5. http://www.etcconnect.com/Community/wikis/products/etcnet2-products.aspx
  6. http://www.pathwayconnect.com/content/view/156/26/
  7. All universes use the same IP
  8. All universes use the same IP, 237.1.1.1 & 237.1.2.1
Personal tools