We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.
Difference between revisions of "OLA DMX Trigger"
From wiki.openlighting.org
(Created page with "ola_trigger executes programs based on the values of DMX data. This allows a lighting console to trigger events like music samples, power point presentations etc. ola_trigger su…") |
(No difference)
|
Revision as of 19:29, 23 December 2011
ola_trigger executes programs based on the values of DMX data. This allows a lighting console to trigger events like music samples, power point presentations etc. ola_trigger supports variable assignment, which offers a flexible way to control the behavior of the
Contents
Usage
Once olad is running, you can run ola_trigger as shown:
ola_trigger example.conf
Some useful options include:
- -l, --log-level <level> Change the logging level, valid values are 0 (minimum logging) to 4 (full logs).
- -u, --universe <universe> Specifies the universe to use.
Config File Syntax
The config file defines which commands are to be run. The config file is separated into two sections: default variable assignment and action definitions.
Slot Actions
Slot actions are specified one per line, in the following form:
[Slot Offset] [Slot Values] [Action]
Each part must be separated by whitespace. Slot offsets range from 0 to 511. Slot values range from 0 to 255.
As an example, the following will run `echo hello world` whenever the value of the first DMX slot changes to 0, 5 or 10.
0 0,5,10 `echo hello world`
Actions are only executed when the value changes. In the example above, if the value of slot 0 in the previous frame was 10, and a frame with slot 0 @ 10 arrived, the action will not be triggered. If a frame with slot 0 @ 5 arrives, the action will execute again.
Value Matching
Values are separated by commas. Ranges can be specified with a hyphen.
1,2,3,4 # Trigger on values 1 through to 4 1-4,10-14 # Trigger on values 1 to 4 and 10 to 14 (inclusive)
The % character the is default match. It triggers for all values that don't have an explicit action configured
0-100 # Values 0 to 100 % # Triggers for everything else (101 - 255)
Command Execution
Variables
Rather than executing a command, an action can set a variable
Special Variables
The variables ${slot_offset} and ${slot_value}
Comments
The # character comments out the rest of the text until the end of the line. This can be used at any location.
Example
A full example config is provided in the tools/ola_trigger directory.
# Example DMX Trigger Config File # Variable definitions ############################################################################### # The default value of slot 2, this won't ever be used, since the variable is # only used with slot 3, which implies we already got data for slot 2. slot_2_value = "nan" # nan isn't special in any way # Triggers ############################################################################### # Slot Trigger Values Action # Slot 0 prints the current value of slot 0 0 % `echo "Slot ${slot_offset} is at ${slot_value}"` # Slot 1 runs a different command line tools 1 1 `ls` 1 2 `ps aux` 1 3 `who` # Slot 2 sets a variable 2 % slot_2_value="${slot_value}" # Slot 3 prints the value of slot3 if slot3 is greater than 50% 3 128-255 `echo "Slot 2 is ${slot_2_value}"`